Melike Abliz

Dedicated Physicist with a strong background in theoretical and experimental physics, specializing in areas such as quantum mechanics, particle physics, and low lemperature physics.

About

I am a dedicated Physicist with a strong background in theoretical and experimental physics, specializing in areas such as quantum mechanics, particle physics, and low temperature physics. Demonstrated ability to conduct complex research, analyze data, and draw accurate conclusions. Skilled in mathematical modeling, computer simulations, and problem-solving. Experienced in collaborating with multidisciplinary teams to achieve research goals and contribute to scientific advancements. Seeking to leverage my expertise and passion for physics to make significant contributions to innovative projects and further expand knowledge in the field. There are my latest achievements: ·        **Designed a vertical septum magnet for the APS-U** I intruded a novel concept to cancel the leakage field of a vertical septum magnet and designed the DC septum magnet for the Advanced Photon Source Upgrade (APS-U) project. We have built the septum magnet and measured its field and found that the septum magnet cancels any leakage field. ·        **I introduced an advanced design structure to the hybrid permanent magnet (HPPM) undulators for the APS-U** I introduced some design skill sets for optimizing the field roll-off, increasing the field, and minimizing the demagnetization field, allowing the narrowing down of the pole width to reduce the magnetic force of HPPM undulators. With the design skill sets, all the HPPM undulators below that I designed for the APS-U have an advanced compact design structure which improves its performance and reduces the material cost of the HPPM undulators by 30%. ·        **Designed APU-U 28-mm period undulator** I designed a 28 mm period HPPM undulator for the APS-U with an advanced compact structure that provides an effective field of 8308 G at a gap of 8.5 mm with a reduced magnetic force of 30%. The measured effective field at the same gap was 9750 G, 4% higher than the design. The devices were either easy to tune or did not need to tune due to the reduced force structure of the design. Also, the measured phase error was 2-3 deg between the open and closed gaps, the smallest phase error measured at the APS. ·        **Designed APU-U 25-mm period undulator.** I designed a 25 mm period HPPM undulator for the APS-U with an advanced compact structure that provides an effective field of 8308 G at a gap of 8.5 mm with a reduced magnetic force of 30%. The measured effective field at the same gap was 8600 G, 4% higher than the design. The devices were either easy to tune or did not need to tune due to the reduced force structure of the design. Also, the measured phase error was 2-3 deg between the open and closed gaps. ·        **Designed APU-U 21-mm period undulator.** I designed a 21 mm period HPPM undulator for the APS-U with an advanced compact structure that provides an effective field of 6674 G at a gap of 8.5 mm with a reduced magnetic force of 30%. The measured effective field at the same gap was 7150 G, 7% higher than the design. The devices were either easy to tune or did not need to tune due to the reduced force structure of the design. Also, the measured phase error was 2-3 deg between the open and closed gaps. ·        **Designed APU-U 13.5-mm period undulator.** I designed a 13.5 mm period HPPM undulator for the APS-U with an advanced compact structure that provides an effective field of 3105 G at a gap of 8.5 mm with a reduced magnetic force of 30%. The measured effective field at the same gap was 3172 G, 2% higher than the design. The devices were either easy to tune or did not need to tune due to the reduced force structure of the design. Also, the measured phase error was 2-3 deg between the open and closed gaps. ·        **Designed APS 14-mm period undulator.** Designed a 14 mm period HPPM undulator for the dynamic compression sector of the current APS, with an advanced compact structure that provides an effective field of 3,364 G at a gap of 8.5 mm with a reduced magnetic force of 30%. The measured effective field at the same gap was 3504 G, 4% higher than the design. Also, the measured phase error was 0.5 - 1 deg between the open and closed gaps.

Legacy Map

Full View

Education

Osaka University

Ph.D, Physics / March, 1997

Osaka

Osaka University

Master of Science

Osaka

Experience

Argonne National Laboratory

Physicist / August, 2009Present

· Magnet design and measurements

Carnegie Institution of Washington

Post Doctor / July, 2006August, 2006

· Magnetic measurement system development for high pressure study with diamond anvil cell at low temperature. · Synchrotron x-ray diffraction for structural phase transition and Equation of State (EOS) study on heavy fermion compounds and low-dimensional superconductor compounds.

Department of Physics, University of Alabama

Post Doctor / July, 2006July, 2007

Set up a magnetic measurement system for the development of high pressure study with diamond anvil cell at low temperature. Conducting independent research project focused on the development of novel measuremet systems for targeted weak magnetic signal.

The Institute for Solid State Physics, Tokyo University

Researcher / April, 1997September, 2005

High pressure study on 4f and 3d electron system by electrical resistance measurements with cubic anvil cell. Quantum critical point (QCP) and non-Fermi liquid behavior in 4f and 3d electron system. Pressure induced superconductor in low dimensional superconductor compounds. Pressure effects on pyrochlore oxide superconductor.

Research Center for Science of Extremal Condition, Osaka University, Japan

Post Doctor / April, 1997March, 2001

· Magnetization measurement with pulsed high magnetic field at low temperature · Theoretical calculation of high field magnetization with crystalline effect · Crystalline field calculation using the magnetic susceptibility data · Magnetization and electrical resistance measurement with SQUID magnetometer

Links & Social Media

Join Melike on NotedSource!
Join Now

At NotedSource, we believe that professors, post-docs, scientists and other researchers have deep, untapped knowledge and expertise that can be leveraged to drive innovation within companies. NotedSource is committed to bridging the gap between academia and industry by providing a platform for collaboration with industry and networking with other researchers.

For industry, NotedSource identifies the right academic experts in 24 hours to help organizations build and grow. With a platform of thousands of knowledgeable PhDs, scientists, and industry experts, NotedSource makes connecting and collaborating easy.

For academic researchers such as professors, post-docs, and Ph.D.s, NotedSource provides tools to discover and connect to your colleagues with messaging and news feeds, in addition to the opportunity to be paid for your collaboration with vetted partners.

Expert Institutions
NotedSource has experts from Stanford University
Expert institutions using NotedSource include Oxfort University
Experts from McGill have used NotedSource to share their expertise
University of Chicago experts have used NotedSource
MIT researchers have used NotedSource
Proudly trusted by
Microsoft uses NotedSource for academic partnerships
Johnson & Johnson academic research projects on NotedSource
ProQuest (Clarivate) uses NotedSource as their industry academia platform
Slamom consulting engages academics for research collaboration on NotedSource
Omnicom and OMG find academics on notedsource
Unilever research project have used NotedSource to engage academic experts

Connect with researchers and scientists like Melike Abliz on NotedSource to help your company with innovation, research, R&D, L&D, and more.